Structural Strength
Maximum pressure that a transducer can withstand without suffering permanent changes in performance or physical deformation represents a primary limit of sensor design. This value is called the proof pressure, and it is usually expressed as a multiple of the rated operating pressure.
Stress Verification
Subjecting a sensor diaphragm to this specific stress level tests the yield strength of the sensing material without causing mechanical failure. The sensor must return to its original zero-pressure output state after the proof pressure is removed. If the material deforms plastically, the calibration shifts permanently, which renders the sensor inaccurate.
Most industrial standards specify a proof pressure of 150 to 200 percent of the maximum operating limit.
Deformation Limit
Metrology labs test proof pressure by pressurizing the sensor to the specified limit and measuring the zero-point return. A drift in the zero-point reading after this test indicates that the sensor did not survive the stress. Manufacturers certify this performance to ensure that pressure spikes do not cause permanent sensor damage.
This verification is performed on a sample basis during production or as a type test for new designs.
Safety Margin
Failure to remain within the limits of this specification can lead to diaphragm rupture or fluid leaks. While a sensor survives proof pressure, it should not be operated continuously at this level. Safety factors built into the system depend on this rating to prevent hazardous leaks.