Failure Mode
The entry of external air or fluid into a closed process system occurs when the internal pressure falls below atmospheric pressure. The prevention of vacuum ingress is critical in sterile environments where the introduction of external air would contaminate the process fluid. Seals and connections must be designed to resist pressure in both directions to prevent this contamination.
This requirement is particularly important for vessels that undergo steam sterilization, which generates a vacuum during the cooling phase.
Elastomeric Seals
Elastomeric seals must be compressed with sufficient force to maintain a seal against both internal pressure and external vacuum. Under vacuum conditions, the seal can be drawn inward, which can create a leak path if the groove design does not support the elastomer. Dual-seal designs with an intermediate barrier fluid are utilized to prevent the ingress of external contaminants.
The barrier fluid pressure is maintained above atmospheric pressure to ensure that any leakage is outward.
System Integrity
System integrity is verified using vacuum decay testing or helium leak detection before commencing production. A vacuum is drawn on the vessel, and the rate of pressure rise is monitored over a specified time to detect leaks. Helium leak detection is more sensitive and can identify very small leak paths that would allow gas ingress.
This testing is performed after each assembly or maintenance operation to ensure that the system is tight.
Leak Limit
Leak limits require that the leak rate remain below the specified threshold under the maximum vacuum level expected during the process cycle.