Immunity Metric
Robustness of galvanic isolators against common-mode voltage transients is evaluated while the device output is held in a fixed logic state. The static Cmti specifies the maximum rate of common-mode voltage rise or fall that the isolator can withstand without changing its output level. This parameter ensures that the system does not experience false turn-on or turn-off events during high dV/dt transients.
Noise Coupling
Internal parasitic capacitances across the isolation barrier act as low-impedance paths for high-frequency common-mode currents. These transient currents can inject noise into the internal receiver logic, causing an unwanted output state change.
Verification Procedure
Testing this parameter involves applying high-voltage pulses of up to several thousand volts across the isolation boundary while keeping the input tied to a stable logic high or low level. The test system monitors the output for any brief transitions or glitches that would violate the static state requirement. Advanced automated test equipment must isolate the signal paths to prevent stray capacitance from distorting the applied transient waveform.
This ensures that the measured static Cmti reflects the true capability of the isolation barrier itself.
System Limitation
Frequency response limits of the internal receiver circuit determine the threshold where the common-mode transition can no longer be rejected. If the transient edge rate exceeds the static Cmti rating, the circuit output will transition falsely, posing a risk of system malfunction.