Structural Deformation
Mechanical tension or compression acting across sealed micro-scale voids alters the structural resonance and membrane flatness of micromachined transducers. Interfacial microcavity stress arises from thermal expansion mismatch, lattice misalignment, and intrinsic film deposition dynamics within etched cavities. Unbalanced stress distributions produce unwanted membrane buckling or curvature in capacitive pressure sensors.
White-light interferometry quantifies out-of-plane surface deflection profiles across the cavity.
Stress Mapping
Raman spectroscopy maps localized mechanical stress fields around the perimeter of micromachined cavities. Compressive stress states induce structural buckling when thin diaphragms exceed critical thickness ratios. Micro-machining processes must balance film stress across multi-layer stacks.
Resonator Drift
Changes in ambient pressure inside sealed microcavities alter internal strain levels, shifting the mechanical quality factor of resonant sensors. Excessive microcavity stress shifts zero-pressure capacitance values and increases temperature coefficient of sensitivity. Annealing cycles at elevated temperatures relax non-uniform intrinsic stresses in silicon nitride membranes.
Long-term creep in thin-film metals causes baseline drift in resonant frequency over years of continuous operation.
Process Control
Plasma-enhanced chemical vapor deposition parameters are tuned to achieve net zero intrinsic stress in structural membranes. Curvature measurement on monitor wafers verifies film stress prior to sacrificial layer etching. Stoney formula calculations relate wafer radius of curvature directly to film stress.