Tomographic Reconstruction
Tomographic reconstruction based on rotational X-ray absorption produces a planar slice through a solid object rather than a complete volumetric rendering. Rotating a source and detector array around a stationary component creates parallel projection data mathematically processed through filtered backprojection algorithms to isolate a specific plane. Laminography differs from conventional computed tomography because the limited angular range of the source movement prevents complete data sampling from every direction.
Geometric blurring occurs outside the focal plane during this process, which degrades off-axis features while maintaining sharp resolution within the targeted stratum.
Focal Plane
Spatial resolution within the reconstructed slice depends strictly on the mechanical stability of the rotational axis and the angular aperture of the scan. Mechanical runout in the gantry introduces artifacts that mimic internal defects during the reconstruction phase. Reconstructed slice thickness diminishes as the total angular range increases, yet physical clearance constraints inside industrial inspection chambers typically restrict the scan angle.
Detector element pitch defines the ultimate pixel size in the final image, while system modulation transfer function dictates the practical limit for discernible flaw sizing.
Scattered Radiation
Off-axis blur intensity correlates directly with object thickness and material density surrounding the plane of interest. Low-energy photons scatter through dense components and strike the detector panel at oblique angles, raising the background noise floor and reducing contrast sensitivity. Anti-scatter grids placed directly in front of the detector mitigate this effect by absorbing photons arriving outside the primary projection paths.
Calibration routines correct for beam hardening artifacts caused by preferential absorption of low-energy wavelengths through thick metallic sections before measurement data reaches the reconstruction software.
Inspection Tolerance
Industrial quality standards mandate specific signal-to-noise ratios and spatial resolution thresholds before a reconstructed slice qualifies for acceptance testing. Measurement uncertainty increases near the edges of the field of view due to geometric distortion inherent in limited-angle acquisition geometries. Third-party metrology laboratories verify these operational limits using reference test blocks containing known internal voids and calibrated wire gauge standards.
Final certification depends upon demonstrating that the measured depth of the focal plane matches the physical position specified in the test procedure.