Transducer Resistance
Electrical resistance measured across the input or output terminals of a symmetric resistive network determines the power consumption and signal matching characteristics of a strain gauge sensor. A stable bridge impedance is necessary to ensure that the excitation voltage remains constant without inducing localized self heating in the resistive foils. The value varies depending on whether it is measured at the excitation terminals or the signal output terminals, with typical values ranging from 120 ohms to 1000 ohms.
This parameter remains bound by the design specifications of the thin film or foil gauges.
Metrological Calibration
Thermal drift during operation alters the nominal resistive values and causes measurement errors. When temperature fluctuates, changes in the gauge material alter the overall bridge impedance and introduce offset errors. Calibrating the system under zero load conditions across the entire operational temperature range compensates for these thermal changes.
This compensation relies on high precision shunt resistors placed in parallel with the bridge arm.
Excitation Constraint
High voltage excitation increases the signal to noise ratio but introduces thermal instability. Managing the excitation level prevents permanent shifts in the resistance.
Circuit Interface
Input impedance of the data acquisition amplifier must exceed the output bridge impedance by several orders of magnitude to avoid loading effects. A mismatch between these values attenuates the sensor signal and introduces non linear measurement errors. Using high impedance buffer amplifiers preserves the integrity of the bridge output voltage.