Sensing Mechanism
Micro-machined semiconductor structures change their internal electrical resistance when subjected to mechanical strain caused by applied pressure. Industrial transducers rely on a silicon piezoresistive element to convert the physical deflection of a diaphragm into a measurable electrical signal. This element is directly bonded to or diffused into a silicon substrate to achieve high sensitivity.
Electrical Circuit
Resistors are arranged in a wheatstone bridge configuration on the semiconductor surface. When pressure deforms the silicon piezoresistive element, the bridge becomes unbalanced, producing a differential voltage that is proportional to the applied force. The high gage factor of silicon produces a much stronger output signal than traditional metal foil strain gages.
Signal Stability
Monocrystalline silicon exhibits low hysteresis and high repeatability over millions of pressure cycles. The elastic properties of the silicon piezoresistive element prevent permanent deformation, ensuring that the sensor returns to its original state once the pressure is released. This mechanical stability is critical for long-term calibration consistency in high-duty cycle hydraulic and pneumatic systems.
Advanced manufacturing techniques deposit protective barriers on the element to prevent moisture or chemical contamination from degrading the delicate circuit paths.
Thermal Sensitivity
Semiconductor materials possess a high temperature coefficient of resistance. Uncompensated thermal changes can cause measurable zero and span drift, requiring built-in temperature measurement and correction electronics to maintain accuracy.