Signal Path
Changes in the output of an eddy current probe occur as the distance between the sensor face and the conductive material surface increases. This lift off trajectory represents a specific path on the complex impedance plane that follows the variation in magnetic coupling. Technicians use this predictable shift to differentiate between actual material flaws and simple variations in probe positioning or surface roughness.
Impedance Plane
Vectorial plots of resistance and reactance provide a visual map for interpreting the interaction between a sensor and a specimen. Because the lift off trajectory moves in a direction distinct from the signal produced by a crack or corrosion, a phase gate can suppress the unwanted noise. Setting the horizontal axis to align with the lift off signal allows for clearer observation of vertical deviations caused by defects.
Compensation Logic
Electronic circuits often use a lookup table or a mathematical model to correct for small variations in the gap between the coil and the metal. When the probe moves away from the surface, the signal amplitude drops significantly, which might otherwise mask a shallow surface crack. Algorithms maintain sensitivity by scaling the gain based on the measured lift off position.
Calibration Block
Reference standards with known thicknesses of non-conductive coatings provide a way to verify the sensor response across a range of distances.