Shielded Conductor
Specialized electrical cables consisting of a center conductor surrounded by two separate concentric conductive shields provide isolation for extremely low current measurements. While a standard coaxial cable has one shield, triaxial cabling adds a second outer layer separated by an additional insulator. This structure allows the inner shield to be driven as a guard.
Connection methods for electrometers and precision semiconductor testers rely on this design.
Noise Rejection
Elimination of leakage currents is the primary benefit of the inner guard shield. By maintaining the inner shield at the same potential as the center conductor, the electric field between them is reduced to zero. The outer shield is typically connected to earth ground to provide protection against external electromagnetic interference.
This dual layer approach lowers the noise floor of the measurement system.
Physical Constraint
Rigidity and diameter are much greater than those of standard coaxial cables. This makes routing difficult in tight spaces. The connectors required for these cables are specialized.
Triboelectric noise can be generated if the cable is moved or vibrated during a measurement.
Cable Verification
Measurement of the insulation resistance between all three conductors is required to confirm cable integrity. Typical values should exceed several teraohms. Connectors must be kept clean to prevent surface leakage paths.
Periodic testing ensures that the shielding and guarding performance has not degraded due to mechanical wear.