Thermal Bypass
Measurement inaccuracy in a temperature sensor occurs when heat flows along the protective stem of the probe between the sensing tip and the external environment. Presence of thermowell conduction error arises because the metal sheath acts as a thermal bridge, pulling heat away from or pushing heat toward the internal sensing element. This creates a temperature difference between the actual fluid and the recorded value.
Stem Immersion
Depth of the thermowell into the process stream is the most influential factor in determining the magnitude of the error. Insufficient immersion allows the ambient temperature at the pipe wall to dominate the sensor reading. A common rule of thumb requires the immersion length to be at least ten times the diameter of the thermowell to minimize this effect.
Temperature Bias
Thermal conductivity of the thermowell material and the velocity of the fluid influence the rate of heat transfer. Stainless steel has a high conductivity that promotes the leakage of heat. In low-velocity gas flows, the convective heat transfer to the tip is weak, making the conduction through the stem more pronounced.
Insulation helps. Engineers calculate the expected error by using fin heat transfer equations to determine the temperature profile along the stem. This calculation is a standard requirement for high-temperature piping design.
Verification Method
Identification of this error is achieved by comparing the readings of sensors with different immersion lengths. Selection of greater insertion depths or materials with lower thermal conductivity reduces the impact of this phenomenon.