Mechanical Shock
Verification protocols determine the structural integrity of microelectronic devices through controlled acceleration events. This procedure, known as mil-std-883 method 2002, assesses the ability of components to withstand physical impacts typical of handling or platform deployment. High-velocity forces occur as the specimen experiences a half-sine or sawtooth pulse with defined peak acceleration and duration limits.
Acceleration Parameters
Pulse waveform characteristics quantify the severity of the stress applied to the package assembly. A calibrated test apparatus produces a shock that matches the target amplitude and duration specifications required by the equipment class. Precision measurements depend upon the mounting fixture stiffness, because resonance in the test board introduces artifacts that obscure the true stress delivered to the component.
Measurement Accuracy
Instrumentation placement near the mounting surface allows for the acquisition of acceleration data without signal distortion. Transducer sensitivity and bandwidth selection ensure that the captured waveform represents the actual energy transfer into the device under test. Calibration against a secondary standard identifies errors in the data acquisition chain before the evaluation starts.
Failure Criteria
Post-shock electrical testing identifies shifts in operating parameters or mechanical fractures that compromise device functionality. Leak detection confirms that the package hermeticity remains intact despite the transient force. Structural survivability is the final metric for evaluating the reliability of the assembly.