Material Nonuniformity
Inherent electromagnetic variations across the surface of a rotating shaft generate false displacement signals in proximity probe measurements. This phenomenon is known as electrical runout, and it arises from localized changes in electrical conductivity or magnetic permeability. These localized variations often originate from non-uniform heat treatment, residual stresses, or local differences in alloy composition.
Even when a shaft is mechanically perfect, an eddy current sensor detects these chemical and physical variations as physical movement.
Measurement Distortion
Distinguishing between true mechanical motion and material variation is critical for machinery protection systems. If the sensor output is not corrected, the electrical runout adds vectorially to the physical displacement, resulting in incorrect vibration readings. This distortion can trigger false alarms or mask actual shaft vibration.
The American Petroleum Institute sets strict limits on the allowable total runout, requiring that the combined mechanical and electrical component remain below a few micrometres.
Signal Compensation
Subtracting the baseline material signature from the dynamic sensor signal solves the measurement distortion. During a slow-roll calibration, the shaft rotates at low speed where mechanical vibration is negligible. The sensor captures the electrical runout profile over a full rotation and stores it as a compensation curve.
During normal operation, the system uses the shaft angle to retrieve and subtract this curve from the active vibration measurement.
Calibration Protocol
Surface burnishing or shaft demagnetization can reduce the electrical runout before the system is commissioned.