Harmonic Analysis
Frequency-domain analytical techniques evaluate exact periodic oscillations in non-linear feedback systems containing relay or switching control elements. Using the tsypkin method determines the exact frequency and amplitude of self-sustained oscillations in relay sensor loops.
Switching Discontinuity
Relay dead-zone characteristics alter oscillation period calculations in bang-bang sensor control circuits. Hysteresis loops in switching elements shift output phase alignment relative to error signal zero crossings. Signal harmonics generated by abrupt switching transitions propagate through plant dynamics.
High-frequency chatter near switching thresholds distorts ideal periodic waveform assumptions.
Computation Protocol
Computer-aided control design systems compute complex infinite series sums across a range of assumed oscillation frequencies. Graphical locus plotting identifies intersection points with negative reciprocal relay gain characteristics to locate periodic solutions. Tangent slope analysis at intersection points determines local stability of predicted limit cycles.
Automated control validation tools verify predicted oscillation frequencies against digital simulation data. Dynamic test benches inject step disturbances into relay sensor loops to observe limit cycle convergence. Test specifications require phase margin calculation at predicted switching frequencies to confirm loop robustness.
Boundary Limit
Analytical accuracy depends on linear plant transfer functions having strict low-pass filtering characteristics. Multiple non-linear elements within a single loop require multi-variable locus methods. System integration rules specify maximum allowable limit cycle amplitude to prevent sensor saturation.
Digital implementation delays introduce phase lags that modify calculated stability loci.