Voltage Recovery
Stability metric defined by the recovery time of a voltage source describes the potential fluctuation following a load transient. This reference rail settling occurs whenever an analog to digital converter draws current from the reference node during a conversion step. Inaccurate measurements result if the voltage has not stabilized before the internal comparator makes a decision.
Dynamic Loading
Interaction between the converter switching network and the external bypass capacitors defines the recovery profile. A large bypass capacitor reduces the magnitude of the voltage drop but can also lead to sluggish reference rail settling if the driving source lacks sufficient current drive. High precision systems often require a dedicated high speed buffer to isolate the reference from the switching transients.
Calibration Impact
Drift in the reference voltage over the duration of a sample set introduces non linearity and gain errors into the measurement. Because reference rail settling is dependent on the sampling frequency, a system calibrated at one rate may show different error characteristics at another. Proper board layout ensures that the return paths for the reference current do not interfere with sensitive analog signals.
Evaluation Procedure
Testing of the settling time involves applying a step load to the rail and monitoring the output with an oscilloscope.