Phase Interference
Unwanted signal appears in the output of a vibratory sensor due to mechanical coupling between the drive and sense axes. In a gyroscope, quadrature leakage is a component of the motion that is ninety degrees out of phase with the actual rotation signal. Error typically results from tiny misalignments in the resonator.
Mechanical Coupling
Small deviations in the manufacturing of the vibrating mass cause the drive force to produce a displacement in the sense direction. Even though quadrature leakage does not represent a real angular rate, its magnitude can be much larger than the signal being measured. Phase difference allows electronic circuits to separate this error from the rate data, provided the phase relationship remains stable.
Stability of the mechanical phase is a prerequisite for accurate demodulation.
Electronic Suppression
Modern sensors use dedicated feedback loops to apply a counter-acting force that nullifies the unwanted motion. By injecting a signal that cancels the quadrature leakage at the source, the system prevents the sense electronics from saturating and improves the overall dynamic range. Precision of this cancellation determines the bias stability of the instrument over its lifetime.
Resonator Integrity
Changes in the mechanical balance of the device over time can cause the error to drift. If quadrature leakage varies beyond the capacity of the compensation loop, the resulting phase shift will bleed into the rate signal and create a heading error. Regular calibration is required to ensure that the nulling parameters remain aligned with the physical state of the hardware.