Position Control
Control systems apply forces to suspended masses using electric fields to maintain stable alignment without mechanical contact. Within high-precision interferometers, electrostatic feedback stabilizes the mirrors against low-frequency drift and seismic motion. This technique uses a set of electrodes positioned behind the mirror to apply calculated attractive forces that counteract external perturbations and keep the optical cavity locked.
It operates as a non-contact actuator, preventing the transmission of acoustic vibrations from the environment into the delicate optics.
Actuator Design
Electrode configurations are optimized to maximize force gradients while minimizing force noise. Sputtered gold patterns on a reaction mass generate the necessary electric fields when biased with high voltages. The force varies quadratically with the applied voltage, necessitating a bias voltage to linearize the actuator response.
Noise Injection
Fluctuations in the applied voltage introduce displacement noise that can limit the sensor performance. To prevent this, low-noise digital-to-analog converters and high-voltage amplifiers are required to drive the electrodes. High-vacuum operation also prevents discharge across the narrow gaps between the electrodes and the suspended mass.
System Stability
Control loops must be carefully tuned to avoid driving internal mechanical resonances of the mirror. Uncompensated phase shifts in the feedback loop can cause the system to oscillate at the resonant frequency of the suspension or the mirror substrate. Filtering techniques are employed to roll off the actuator response at high frequencies.