Kinetic Noise
Stochastic fluctuations resulting from the thermal energy of a medium exert continuous, random forces on microscopic mechanical structures. Brownian motion represents the fundamental noise floor for high-resolution micro-electromechanical sensors. Molecular collisions produce displacement noise that limits the detectable signal in accelerometers and gyroscopes.
Thermal Agitation
Collisions between molecules of the surrounding gas or internal lattice phonons and the proof mass drive these random oscillations. In the context of a vacuum-packaged sensor, brownian motion scales with the square root of the absolute temperature and the damping coefficient.
Noise Equivalent
The spectral density of the force produced by this thermal activity remains white across most of the operational bandwidth of the device. Designers calculate the brownian motion contribution by evaluating the mechanical resistance of the system, where higher damping leads to a higher noise floor. Reducing the mass of the sensor increases the susceptibility to these fluctuations, creating a trade-off between device size and resolution.
Precise measurement of the noise floor allows for the separation of electronic interference from these intrinsic mechanical limits.
Vacuum Influence
Packaging at lower pressures reduces the collisions that contribute to mechanical noise. Brownian motion effects are minimized when the quality factor of the resonator is high.