Topography Assessment
An optical method used to map the surface topography of electronic packages and substrates provides a non contact solution for warpage analysis. Utilizing shadow moire metrology involves projecting a grating pattern onto a specimen and observing the interference fringes created by its shadow.
Fringe Interpretation
Geometric patterns formed by the interaction of the grating and the surface reflect the height variations across the component. The distance between the fringes indicates the steepness of the warpage or the degree of flatness. Computer algorithms translate these visual patterns into a three dimensional model of the part surface.
Thermal Profiling
Integrated heating elements allow the system to measure warpage across the entire reflow temperature profile. This capability identifies how a package deforms during the soldering process, which is critical for preventing head in pillow defects or open joints.
System Calibration
Accuracy depends on the precise alignment of the light source and the camera sensor relative to the grating. Standard reference flats are used to verify the resolution and the linearity of the measurement across the field of view. Shadow moire metrology provides a repeatable way to qualify the flatness of large area substrates before they enter the assembly line.