Reset Toggling
Serial communication protocols apply specific sequences to resolve hardware lock conditions on a data bus. Implementation of nine-clock recovery allows a bus master to regain control without resetting the power to the entire system. This procedure addresses a failure mode where a peripheral device has lost synchronization with the master clock during a read sequence.
Pulse Timing
Generating nine individual transitions on the clock line mimics the transmission of a full byte followed by a non-acknowledge bit. Through nine-clock recovery, the master provides enough cycles for any slave device stuck in a data-output state to release the serial data wire. The master observes the state of the data line after each pulse to detect when the line becomes free.
Once the data line is high, the master sends a stop bit to clear the bus. This sequence ensures the slave state machine returns to an idle condition.
Driver Implementation
Firmware drivers must be capable of taking direct control of the clock and data pins to perform this task. During nine-clock recovery, the standard hardware controller is bypassed because it cannot generate clocks while the data line is held low by another device. The routine transitions the clock pin from high to low and back while maintaining a specific frequency that the slave can recognize.
Compliance Boundary
Verification of the bus logic confirms that this method is a standard requirement for SMBus compatible systems. While nine-clock recovery is a reliable part of robust bus management, it only works if the slave device is still functional. Physical shorts require different mitigation strategies.